Electrical cable shielded PVC

Cores
Length
Product number: KAB-2017-19.2

Shielded Cables

A MUST(!) for wooden houses or construction with lightweight walls!

Electrical cables are wrapped with a protective film and then with an aluminum foil. An additional grounding wire runs internally, which has direct contact with the aluminum foil. The occurring electrical fields of the electrical cables are directly intercepted there.


Please ensure that the appropriate cavity or plaster sockets are also ordered!

Important! Instructions for the electrical specialist company

When installing, be sure to connect the earth connection of, for example, the plaster box with the earth connection of the used shielded installation cable (yellow-green with yellow-green, never with the neutral wire), protect the bare neutral wire with insulation tubing (no conductive components in the connection box), and lead it (neutral wire = shield connection, without connection to yellow-green) preferably up to the potential equalization bar or distribution box. Always apply the neutral wire on one side only, not as sometimes common in HF technology, connecting both sides to earth. Do not use mixed unshielded and shielded installation cables.

Use:

PVC control cable with copper shielding. Used as shielded signal and pulse cable in measurement, control and regulation technology, whereby the shielding serves as protection against external influences, such as electrical magnetic fields, interference frequencies, and the like.


Structure:

  1. Copper conductor, bare, fine-stranded
  2. Core insulation made of polyvinyl chloride (PVC)
  3. Wrapping with plastic film
  4. Braided tinned copper wires
  5. Outer sheath made of polyvinyl chloride (PVC), gray, largely oil-resistant

Standards:

In accordance with DIN VDE 0281, DIN EN 60228 Class 5 (conductor design), HD 308 S2 (core identification for colored cores), core identification JZ: 1 core green-yellow, other cores black with numbers, core identification OZ: all cores black with numbers.

Technical data:

Rated voltage Uo/U: 300/500 volts, test voltage: [V]AC 2000, temperature range (mobile): -5°C to +70°C, temperature range (fixed installation): -30°C to +70°C.

Conductor bare, solid class 1 acc. to DIN 0295, sheath colour light grey RAL 7035, shield (electric field, 50 Hz mains voltage) plastic-coated aluminium strip with one tinned filler wire (copper, bare, solid), copper filler wire: 1.13 mm

Core insulation, halogen-free (cross-linkedPE polyethylene 2XI1) according to DIN 0276 part 604 

Plastic inner sheath and outer sheath halogen-free PE-polymer compound HM2 acc. to DIN 0250 part 214 
– Polymers PE-EVA mixture Granulate
– Flame retardant Aluminium trihydroxide (ATH) powder 

No plasticisers processed 

Rated voltage U0/U 300/500 V, current load according to VDE 0100 

Structure according to DIN 0250 part 204/209, marking according to DIN 0293 

Test method according to DIN 0472, part 266-2-4 test type C or IEC 332.3 

Alternating test voltage 50 Hz, 2000 V 

Bending radius according to DIN 0298, not moved approx. 4 x diameter 

All standards related to Germany (VDE). NO approval outside the EU.